"Our water problems in the basement were severe and complex. Your company came up with the right combination of treatments to solve our problems. Upon completion of the project we received over four inches of rain in two days; the true test was immediate. Our basement was bone dry for the first time in 10 years. Thank you, EverDry, for the great service."
-Charlie Ruhmann, Satisfied EverDry Customer
|
|
 |
| Stabl-Wall Specs |
INDIANA AREA'S PREMIER FOUNDATION REPAIR COMPANY |
CALL NOW! 1-800-686-3267 |
|
|
 |
|
 |
Stabl-Wall Reinforcing Fiber
| Parameter |
Minimum Value |
Governing Test Method |
| Tensile Strength |
500,000 psi |
ASTM D3039 |
| Tensile Strain |
1.5% |
ASTM D3039 |
| Tensile Modulus |
30,000,000 psi |
ASTM D3039 |
| Color |
Black |
None |
| Roll Width |
24 inches |
None |
| Roll Length |
270 feet |
None |
Stabl-Wall Adhesives: MINIMUM VALUES
| PARAMETER |
Stabl-Wall
Primer |
Stabl-Wall
Paste Filler |
Stabl-Wall
Bonding
Adhesive |
Governing
Test
Method |
Color
Part A
Part B
Mixed |
Amber
Clear
Amber |
Tan
Charcoal
Tan |
Amber
Clear
Amber |
None
None
None |
Mix Ratio (Volume)
Part A:Part B |
3:1 |
3:1 |
3:1 |
None |
Working Time @
70 F |
15 Minutes |
30 Minutes |
35 Minutes |
1 Gallon
Sample |
| Shelf Life |
12 Months |
12 Months |
12 Months |
None |
| Tensile Strength |
2,000 psi |
2,000 psi |
7,000 psi |
ASTM D638 |
| Tensile Strain |
0.30 |
0.05 |
0.03 |
ASTM D638 |
| Tensile Modulus |
100,000 psi |
230,000 psi |
400,000 psi |
ASTM D638 |